Prof. Ing. Miloslav Jokl, DrSc.

05.10.2009
Problems following the application of optimal operative temperatures estimated on the basis of PMV and the necessity to apply correct values into the new Czech Government Directive No. 523/2002 Code led to experiments based on the physiological human body response instead of on solely man’s feelings in a defined environment. On the basis of experiments on 32 subjects (university students) it has been possible to estimate: a) total balance of hygrothermal flows between the human body and environment, b) the optimal operative temperature as a function of the subject’s activity, c) the thermoregulatory range for each optimal operative temperature, i.e. maximal (category Cmax) limited by the beginnings of sweating, minimal (category Cmin) limited by the beginnings of shivering (category C can be applied to the natural ventilated buildings), optimal (comfort level – category A) defined by time constant 0.368 (can be applied to air conditioned buildings) and submaximum (decreased comfort level – category B) defined by time constant 0.632 (can be applied to buildings with basic air conditioning systems).
31.07.2009
Člověk nemá speciální čidla vlhkosti a vzhledem k uvedeným experimentálním výsledkům, lze snížit v nezbytných případech relativní vlhkost vzduchu na 15%, ne však již níže. Dolní limit optima dle vládního nařízení č. 361/2007 Sb. je 30%, doporučuje se 35% jsou-li v interiéru použity antistatické materiály; není-li tomu tak, pak 40%. Relativní vlhkost vzduchu klesá s nadmořskou výškou a je-li snížena, vytváří vjem jednak chladnějšího, jednak čerstvějšího vzduchu.
25.09.2008
According to EN ISO 7730 the estimation of RTA (trA-trB) is prescribed; it has been measured by Indoor Climate Analyzer of Bruel and Kjaer. It was proved that a new instrument, globe stereothermometer, developed in Malý´s research group, can be applied for this purpose.It is a globe of 15cm in diameter divided into 6 segments; the surface temperature of each segment is called stereotemperature (tstereo). The mean value of all six stereotemperatures equals to globe temperature (tg). Radiant Temperature Asymmetry can be estimated from equations (6),(7)and (8) and from Fig. 7.Stereothermometer is produced by SIPOCH Ltd. Prague. The company also developed electronics and technology of the instrument (dipl. Ing. L. Vajner). This paper introduces new method for radiant temperature asymmetry estimation.

Nabízíme Vám možnost BEZPLATNÉHO odběru e-mailového zpravodajství

Přehled příspěvků publikovaných na oborovém portálu BOZPinfo zasílaný každý pátek odpoledne

Provozovatel portálu

Výzkumný ústav bezpečnosti práce, v. v. i.
Jeruzalémská 1283/9
110 00 Praha 1

Sociální sítě VÚBP

facebook linkedin instagram buzzsprout X youtubepinterest

Kde nás najdete

X

Přihlášení

Zapomněli jste heslo?
zašleme vám nové na váš e-mail